Teledyne LeCroy HD4096 High Definition Oscilloscope Technology
The 1st Digital Storage Oscilloscope (DSO) was developed in 1985 by Dr Walter LeCroy, founder of LeCroy Corporation (now Teledyne LeCroy). LeCroy remains one of the three largest oscilloscope manufacturers in the world.
As electronic digital oscilloscopes have been better over the decades, great advancements have already been made in the areas of bandwidth, sample rate, and record length, but right up until recently, little improvement has been produced in analog-to-digital convsersion app (ADC) resolution. Many oscilloscopes provide an eight-bit ADC which digitizes signals using two hundred and 60 six quantization levels. Teledyne LeCroy has now introduced twelve-bit ACD technology along with 4, 096 quantization levels. That greatly increases the potential of oscilloscopes to be able to accurately capture plus display waveforms instructions with a 16 instances greater resolution more than the eight-bit scopes.
The Teledyne LeCroy HD4096 High-definition technology adds resolution in addition to measurement precision to the display of oscilloscope waveforms. technology accelerator consists of a new high sample charge of 12-bit ADCs, high signal-to-noise rate amplifiers, and low-noise system architecture. HD4096 allows oscilloscopes employing this technology, many of these as the Teledyne HDO4000 and HDO6000 series, to capture and display alerts of up in order to 1GHz with high sample rate, plus resolution 16 times high than standard oscilloscopes.
Oscilloscopes employing the HD4096 hd technology render information with higher accuracy and resolution as compared to 8-bit oscilloscopes. High resolution sampling of upward to 2 . 5GS/s is made feasible with 12-bit ADCs. A 55dB signal-to-noise ratio provided simply by the high-performance type amplifiers provides spectacular signal fidelity, and even delivers immaculate signals for digitizing throughout the ADC. The low noise architecture defends captured signals coming from interference, allowing the oscilloscope to display waveforms with great accuracy.
Twelve parts of vertical quality is sixteen period higher resolution compared to eight bits. The particular discrete levels acquired with HD4096 technological innovation markedly reduce quantization error. Eight-bit systems inject a higher level of quantization error into waveforms, resulting in less accurate representation. Twelve-bit HD4096 technology precisely displays signals using minimal quantization problem.
Oscilloscopes that employ HD4096 are the particular Teledyne LeCroy HDO4000 and HDO6000 Large Definition Oscilloscope series.
The HDO4000 oscilloscopes offer twelve-bit ADC resolution (up to fifteen-bit with improved resolution); bandwidths of 200MHz, 350MHz, 500MHz, and 1GHz; 2. 5GS/s sample charge; memory as much as 25Mpts/Ch (50Mpts interleaved). WaveScan advanced search in addition to find, LabNotebook paperwork and report technology, and History Function waveform playback usually are standard.
The HDO6000 series offers twelve-bit ADC resolution (up to fifteen-bits using enhanced resolution); 350MHz, 500MHz, 1GHz bandwidths; 2. 5GS/s sample rate; up in order to 250Mpts/Ch memory. Array analyzer mode, WaveScan advanced search and even find, History Mode waveform playback, Strength Analysis software, JITKIT clock-data jitter analysis, serial data bring about and decode, LabNotebook report generation, superior trigger tools like TriggerScan and computer software assisted trigger; almost all are standard.